Nominal pressure (MPa)
Test pressure 1.0 1.6 2.5 4.0
Shell strength test 1.5 2.4 3.75 6.0
Sealing test (liquid) 1.1 1.76 2.75 4.4
Sealing test (gas) 0.5~0.8 MPa
Applicable medium Water, steam, gas, dust oil, nitric acid, acetic acid alkali, etc.
Applicable temperature ≤200℃
Electric fixed ball valve is a kind of rotary ball valve with a rotation angle of 90°. It has excellent sealing performance, large flow capacity, small flow resistance coefficient, convenient maintenance and long service life. Can flow without loss. Equipped with high-performance actuators such as FOLS, the products are usually used in occasions with strict sealing requirements. In addition to controlling gas, liquid and steam media, they are also suitable for controlling sewage and media containing fibrous impurities. They are widely used in petroleum, chemical, metallurgy, Light industry, papermaking, power station, refrigeration and other fields of work.